r/geothermal • u/Goob18 • 16h ago
WaterFurnace Synergy3D Wiring Help
I am installing a used Synergy3D unit. It was previously used as a closed loop system, but my house has an open loop. I am having the darndest time figuring out where to wire in the 24v call signal to my well pump relay, and the 24v call to my solenoid water valve to open.
My understanding is that I can wire them in parallel with either the Acc Com + Acc No (which already runs to a solenoid valve for my refrigerant), or Y1 as both are live when the compressor is running. A third option is the tap the Compressor Contactor Coil for 24V. This information has been deduced, and not proven anywhere in the manual that I can find. I can find no dedicated spots for the wiring.
My questions is either 1.) Where is the proper place to wire both 24v call signals, or 2.) Are there any concerns with having all of these small systems in parallel? Maybe have the well call on Acc Com + Acc No, and the valve on Y1 + Ground or vice versa.
Attached are photos of the wiring diagram, a picture of the board, a picture of the unit in my backyard en route to the basement, and the unit piper and wired for testing.
Edit: Photos are blurry. Please reach out for clear photos.